Codemath.com


Residential Single Phase Service - Canada
100A, Mast, Copper Conductors, #6 Bare Neutral (if allowed)

Part Numbers Courtesy of Eecol Electric
1711 MacRae Drive, Regina, Sask., S4N 0S4
Phone (306) 525-2317 / Fax (306) 525-3752
Hours of operation: Mon-Fri 7:30 am to 4:30 pm

CAUTION
A bare neutral is not allowed in all circumstances.
Reduced neutral size is only allowed in some circumstances.

Material Check List
Heading Qty Description Eecol Electric Part No.
       
Mast Kit
KIT-200MJ
  Mast Head (one included in each kit)  
  Mast Rack (one included in each kit)  
  Mast Flange (one included in each kit)  
  1¼" Mast Reducer (one included in each kit)  
  Mast Strap (one included in each kit)  
  Lag Bolts for mast strap (two included in each kit)  
  Mast Clamp with through-bolt and nut (one included in each kit)  
  4" x 4" Washer for through-bolt in attic (one included in each kit)  
Other Mast  
 
  2" x 2" Washer for through-bolt in building 1822SW11
  8 Foot Mast 2508
  10 foot Mast 2510
  Roofing Tar  
  Plastic Surface Blank Cover (cover through-bolt hole into building)  
  #6 X 1¼" Wood Screws to attach blank cover to wall 10210
  1¼" Screws to secure flange to roof 10210
Meter  
 
  100 Amp Overhead Meter Socket BE1-TCV
  1¼" Meter Socket Hub MH12X
  1¼" Close Nipple (between mast reducer and meter hub) GALV NIP 1 1/4 X 1 5/8
  Back Board (behind meter socket) MM23
  1" screws (attach back-board to wall) 10390
  2" Screws (attach meter to wall through back-board) 10430
  Washers (for 2" screws) 61511
Conduit  
 
  1" EMT (between meter socket and panel) EMT CONDUIT 1IN
  1" EMT Water Tight Connectors CI5808-IT
  1" Set Screw Connector CI5408-IT
  1" EMT Water Tight Couplings CI5908
  1" EMT Straps CI1308
  Screws (attach straps) 10390
  1" LB (entry into building and sealing) CILBA-1
  1" Nylon Bushing (inside meter socket) CI2708
  Silicone Sealant (seal penetration into building)  
  1" Rigid Coupling (extend conduit inside building) GALV RIG CPLG 1IN
  1" Nipple (extend conduit inside building) GALV NIP 1XCLOSE
  1" Locknuts (for nipple) CI1708
Panel  
 
  Panel with 100 Amp Main Breaker CHOM3060M100GC
  Plywood backing for Panel  
  Vapor barrier (behind plywood for panel)  
  1½" Screws (attach plywood to wall) 10410
  Concrete Anchors (attach plywood to wall) DIA37
  ¾ " Screws (secure panel to plywood) 10370
  Sealing Tape for vapor barrier  
Service Wiring  
 
  #6 Bare Copper BARE CU 6(STR)
  #3 Copper RW90 Black RW90 3CU BLK
  Sealing Material (seal inside conduit entering building) CI-DUCT-1
  Wire Lube 31-358
Grounding  
 
  #6 AWG Bare Copper BARE CU 6(STR)
  Ground Clamps for Incoming Water Line (if metallic) CI3106
  Ground Plate (if not using water line) 1016BTB
  2 Ground Rods (if not using water line) 815800
  Ground Clamps for Ground Rods JAB34H
Bonding  
 
  1" Ground Bushing (inside panel) CI2608
  #6 AWG Bare Copper BARE CU 6(STR)
  Ground Clamps for gas, water, sewer CI3106
  Connector where ground/bond wire leaves panel CI4040
  Cable Ties (securing ground to water line) TY523M
Breakers  
 
  Range Breaker CHOM230
  Dryer Breaker CHOM240
  Air Cond. Breaker CHOM225
  Kitchen Counter Plug 2 Pole 15 amp Breaker CHOM215
  Kitchen Counter Plug 2 Pole 20 Amp Breaker CHOM220
  Kitchen Counter Plug 20 amp Breaker CHOM120
  AFCI breaker (bedroom plugs) CHOM115AFI
Panel Wiring  
 
  ½" NMD connectors CI4040
  ¾" NMD connector (range cable) CI806
  Junction Boxes (extending wires)  
  Junction Box covers (extending wires)  
  14/2 NMD (extending wires) 14/2 NMD
  14/3 NMD (extending wires) 14/3 NMD
  10/3 NMD (extending or replacing dryer wiring) 10/3 NMD
  8/3 NMD (extending or replacing range wiring) 8/3 NMD
Old Wiring  
 
  GFI Blank Front (ungrounded circuits) 8590-W
  Box for GFI Dead Front BC2304
  Surface cover for GFI Dead Front Box 80401-NW
  Plastic Connectors (knob & tube entering a box) NMLT5
       
       